Fisher GX Control Valve And Actuator System

Fisher GX Control Valve And Actuator System

Any questions?

Peder Hvidberg
Account Manager
Phone. 2178 5053

Peder.Hvidberg@askalon.dk

Questions about the product?

Fill out the form below and we will contact you with answers to your questions






En komplet og robust reguleringsventil som klarer de fleste processmedier. Den er enkel at dimensionere. Aktuatoren bliver bestemt automatisk. Findes til både DIN och ANSI tilslutninger i størrelsen DN15-DN150, 1/2"-6". Fisher™ GX ventilen findes med integreret positioner DVC2000. Muligt at anvende lufttillførsel på 6 bar hvilket muliggør at regulere med høje trykfald. Trimdele er udskiftelige.
 

Certifications CRN, CUTR, Fugitive Emission, PED, SIL capable
Critical Service Noise Abatement, Cavitation, Erosive, Low Flow, Corrosive, General Service
Flow Characteristics Equal Percentage, Linear, Special Characterization
Material Carbon Steel, Stainless, Duplex, Alloy
Operating Temperature Standard Temperature, High Temperature
Pressure Class CL150, CL 300, PN 10/16, PN 10/16/25/40, PN 25/40
Process Connection Type Flanged
Shutoff Class Class IV (FCI 70-2), Class V (FCI 70-2), Class VI (FCI 70-2)
Valve Size NPS 1/2, NPS 3/4, NPS 1, NPS 1-1/2, NPS 2, NPS 3, NPS 4, NPS 6
Valve Size Standard NPS

Bolted Bonnet:

Certifications CRN, CUTR, Fugitive Emission, PED
Critical Service Noise Abatement, Cavitation, Erosive, Low Flow, Corrosive, General Service
Flow Characteristics Equal Percentage, Linear, Special Characterization
Material Carbon Steel, Stainless, Duplex, Alloy
Operating Temperature Standard Temperature, High Temperature
Pressure Class CL150, CL 300, PN 10/16, PN 10/16/25/40, PN 25/40 per EN12516-1
Process Connection Type Flanged raised face– Butt weld-ends; Socket weld-ends NPT ends
Shutoff Class Class IV (FCI 70-2), Class V (FCI 70-2), Class VI (FCI 70-2)
Valve Size NPS 1/2, NPS 3/4, NPS 1, NPS 1-1/2, NPS 2, NPS 3, NPS 4, NPS 6
Bonnet Style Options Standard, Extension (High Temp), Cryogenic Extension, and Bellows – all featuring bolted construction.
  • Easy to size and select.
  • No actuator sizing required; selection is automatic.
  • Optimized actuator allows for a wide range of air supply.
  • Engineered for easy maintenance.
  • Maximum part commonality across sizes.
  • Trim is replaceable.
  • Low lifetime costs.
  • Robust, low-profile design.

Bolted Bonnet version:

  • Compact and robust bolted bonnet design
  • Optimized actuator allows for a wide range of air supply
  • Engineered for easy maintenance
  • Maximum part commonality across sizes
  • Replaceable trim
  • Low lifetime costs
  • Robust, low-profile design
  • Compact multi-spring pneumatic actuator
  • Available with integrated, easy-to-calibrate FIELDVUE™ digital valve controllers
  • High-capacity design
  • Valve body flow passage optimized for flow stability
  • Optional metal bellows seal